Recommended system size: 2.2 kW

10 kWh/day · 5.6 peak sun hours in Ghazni City

Solar System Size Calculator result

2.2 kW

10 kWh/day · 5.6 peak sun hours in Ghazni City

Recommended system size
2.2 kW
Panels
4 × 585 W
Roof area required
≈ 10 m²
Hybrid inverter
3 kW
Battery bank
1 × 5.12 kWh LiFePO4 (2.92 kWh needed)
DC cable
25 mm² · 1.34% drop
Charge controller / DC breaker
58 A · 60 A
Orientation
True South · 29° tilt
Estimated yearly output
3,597 kWh
Estimated savings
AFN 3,597/mo · AFN 43,164/yr
CO₂ avoided
1,619 kg/yr ≈ 77 trees

Based on 300 kWh per month in Ghazni City, 585 W panels and 6 hours of backup. Estimates use 20% system losses, 15% inverter headroom and AFN 12/kWh. A free site survey confirms the final design.

About this result

Ready to switch off the generator for good?

Book a free site survey in Ghazni. We measure your load, design the right system and give you a fixed written price.